This page was exported from Exams Labs Braindumps [ http://blog.examslabs.com ] Export date:Sat Sep 28 7:32:32 2024 / +0000 GMT ___________________________________________________ Title: [2022] Pass Huawei H12-411_V2.0 Test Practice Test Questions Exam Dumps [Q102-Q116] --------------------------------------------------- [2022] Pass Huawei H12-411_V2.0 Test Practice Test Questions Exam Dumps Verified H12-411_V2.0 dumps Q&As - H12-411_V2.0 dumps with Correct Answers NEW QUESTION 102The following air conditioners do not need to install cooling towers.  Air-cooled direct expansion air conditioner  Water-cooled air conditioner  Air-cooled chilled water air conditioner  Water-cooled chilled water air conditioner NEW QUESTION 103According to the degree of equipment concentration, the air conditioning system can be divided into____________ . centralized, semi-centralized, decentralizedNEW QUESTION 104Huawei Monitoring System NETECO Support hierarchical network management function.  True  False NEW QUESTION 105There are generally two types of variable air volume ventilated floors, one is through an adjustable air valve, and the other is a dedicated ventilated floor plus adjustable fans.  True  False NEW QUESTION 106The increase of cabinet power density will lead to the emergence of local hot spots in the computer room, and row-level air conditioners can solve local problems. The hot spot is too high.  True  False NEW QUESTION 107The following are air-cooled row-level air conditioners ____________ . Netcol5000-ANEW QUESTION 108The ____________ function of the dynamic loop monitoring system can display the real-time status of the equipment. real-time signalNEW QUESTION 109The following ____________ are not harmful effects of electric current on the human body. splittingNEW QUESTION 110One ups The capacity is 200KVA, Its output power factor is 0.9, Then it can drive at most ____________ load. 180KWNEW QUESTION 111____________ is used to ensure that the fire extinguishing agent has been sprayed out in a specific jet form to promote the rapid gasification of the fire extinguishing agent and reach the fire extinguishing concentration in the protected space. NozzleNEW QUESTION 112UPS Also known as AC uninterrupted power supply system, for online upsWhen the AC input is normal, the____________ will supply power to the system. inverterNEW QUESTION 113When the sunroof actuator senses a smoke alarm, it cannot control the turning sunroof to open automatically.  True  False NEW QUESTION 114In the air-conditioning system, the function of the ____________ is to use water cooling or air cooling to cool the high-temperature and high-pressure gas discharged from the compressor and release heat to the outside world. condenserNEW QUESTION 115UPS Common system configurations are N system,N+X system,2N system.  True  False NEW QUESTION 116When the battery electrolyte leaks, ____________ treatment is more appropriate. wipe it clean with a rag with gloves on, and check if it needs to be replaced Loading … H12-411_V2.0 certification guide Q&A from Training Expert ExamsLabs: https://www.examslabs.com/Huawei/HCIA-Data-Center-Facility/best-H12-411_V2.0-exam-dumps.html --------------------------------------------------- Images: https://blog.examslabs.com/wp-content/plugins/watu/loading.gif https://blog.examslabs.com/wp-content/plugins/watu/loading.gif --------------------------------------------------- --------------------------------------------------- Post date: 2022-06-05 13:33:04 Post date GMT: 2022-06-05 13:33:04 Post modified date: 2022-06-05 13:33:04 Post modified date GMT: 2022-06-05 13:33:04